Quantification of historical dust exposures in the diatomaceous earth industry [0.03%]
埃洛石工业历史粉尘接触水平量化研究
N S Seixas,N J Heyer,E A Welp et al.
N S Seixas et al.
Quantitative estimates of dust exposure in a diatomaceous earth (DE) mining and milling operation have been derived based on air sampling records for the period 1948-1988. A total of 6395 records was included in the analysis. Conversion of ...
A comparison of exposures to refractory ceramic fibres over multiple work shifts [0.03%]
多个工作班次的耐火陶瓷纤维暴露量比较研究
G S Hall,C H Rice,J E Lockey et al.
G S Hall et al.
As part of an ongoing, industry-wide study in the manufacture of refractory ceramic fibres (RCF), time weighted average (TWA) exposures have been collected at five facilities according to a standardised protocol. Work activities were groupe...
Multicenter Study
The Annals of occupational hygiene. 1997 Oct;41(5):555-60. DOI:10.1016/S0003-4878(97)00011-2 1997
European sampling intercomparisons for aromatic and chlorinated hydrocarbons in workplace air [0.03%]
工作场所空气中芳香烃和氯化烃的欧洲采样对比试验
E Goelen,M Lambrechts,F Geyskens
E Goelen
Thirty-eight laboratories of the EU Member States, representing government, manufacturers of personal samplers, industrial and university laboratories have participated in a quality assurance scheme which allows to evaluate errors associate...
Multicenter Study
The Annals of occupational hygiene. 1997 Oct;41(5):527-54. DOI:10.1016/S0003-4878(97)00016-1 1997
Z Adamis,E Tátrai,K Honma et al.
Z Adamis et al.
The aetiology of hard metal lung disease has not been clarified so far. The pulmonary toxicity of respirable dusts collected in a hard metal factory was studied in vivo in rats. The effect of the samples was examined 1, 4, 7 and 30 days aft...
The variability of exposure over time: a prospective longitudinal study [0.03%]
时间推移下的暴露变异性:一项前瞻性纵向研究
C Peretz,P Goldberg,E Kahan et al.
C Peretz et al.
Four hundred and forty personal air measurements were carried out on 54 workers, employed in the main processes in six different factories (6-13 in each). Potential exposure was to lead, benzene and dust. Ten randomly repeated hygiene surve...
A comprehensive strategy for the assessment of noise exposure and risk of hearing impairment [0.03%]
全面评估噪声暴露和听觉损伤风险的策略
J Malchaire,A Piette
J Malchaire
A comprehensive strategy is presented for the evaluation of the daily noise exposure level [LEX,d in dB(A)] and the assessment of the risk of hearing impairment. The risk is defined as the probability for a worker with a given exposure hist...
Effects of combined exposure to noise and toxic substances--critical review of the literature [0.03%]
噪声和有毒物质联合作用的听力损伤效应——文献综述
R Cary,S Clarke,J Delic
R Cary
A number of studies have been conducted in recent years investigating the potential effects on various health endpoints of the combination of noise and a variety of different industrial substances. This review indicates that the information...
Timing of sample collection for biological monitoring of occupational exposure [0.03%]
职业性接触生物监测的采样时机
V Fiserova-Bergerova,J Vlach
V Fiserova-Bergerova
The timing of sample collections for the biological monitoring of occupational exposure profoundly affects the resulting data. Sampling time with respect to the day in the working week and the end of exposure is crucial for measurements of ...
Accuracy and reproducibility of calibrations on the skin using the fives fluorescence monitor [0.03%]
五波荧光仪的皮肤校正准确性和重复性
M W Roff
M W Roff
Dermal contamination from products such as pesticide formulations may be measured by adding a fluorescent dye as a tracer, and photographing the glow of the dye on the skin under ultraviolet light. The Fluorescence Interactive Video Exposur...
Dermal exposure of amateur or non-occupational users to wood-preservative fluids applied by brushing outdoors [0.03%]
业余或非职业人员在户外刷涂木材防护液的皮肤暴露风险
M W Roff
M W Roff
The results of an experiment to determine the likely dermal exposure of amateur or occasional users to wood-preservative fluids, applied by brushing onto a wooden fence outdoors are presented. Exposure was measured using FIVES, a fluorescen...