Comparison of Intraoperative Parameters between Two Handpieces in One-Handed Phacoemulsification with Active Fluidics [0.03%]
一次性手持超声乳化抽吸对比分析
Jerónimo Araño-Ferrer,Ana Beatriz Medina-Perez,Cyntia Solis-Hernandez et al.
Jerónimo Araño-Ferrer et al.
Purpose: To compare anterior chamber stability and surgical efficiency in one-handed phacoemulsification, comparing Ozil and Active Sentry (AS) handpieces. Methods: Observational and comparative study. Selected patients were divided into tw...
Comment on: Vitreous-lens interface changes after cataract surgery using active fluidics and active sentry with high and low infusion pressure settings [0.03%]
主动液路和高低灌注压力设置的白内障手术后玻璃体晶状体界面的变化及评述
Aafreen Bari,Namrata Sharma,Tushar Agarwal
Aafreen Bari
Safety and prognosis of phacoemulsification using active sentry and active fluidics with different IOP settings - a randomized, controlled study [0.03%]
主动式 Sentry 和不同眼压设置的主动流系统的超声乳化术的安全性和预后效果——一项随机对照研究
Shouyan Wang,Jianjian Tao,Xiao Yu et al.
Shouyan Wang et al.
Methods: Age related cataract patients who met the inclusion criteria and underwent phacoemulsification by using active sentry handpiece and active fluidics system.
Randomized Controlled Trial
BMC ophthalmology. 2024 Aug 16;24(1):350. DOI:10.1186/s12886-024-03626-z 2024
Intraoperative Performance and Early Postoperative Outcomes Following Phacoemulsification With Three Fluidic Systems: A Randomized Trial [0.03%]
超声乳化白内障摘除术中三种灌注系统的性能及术后早期效果的随机对照试验
Vaishali Vasavada,Deepa Agrawal,Shail A Vasavada et al.
Vaishali Vasavada et al.
Purpose: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics.
Randomized Controlled Trial
Journal of refractive surgery (Thorofare, N.J. : 1995). 2024 May;40(5):e304-e312. DOI:10.3928/1081597X-20240314-02 2024
Phacoemulsification using an Active Fluidics System at Physiologic versus High IOP: Impact on Anterior and Posterior Segment Physiology [0.03%]
生理压力与高强度房水动力超声乳化白内障摘除术对眼前节和眼后段生理的影响
Matthew P Rauen,Hillery Joiner,Robyn A Kohler et al.
Matthew P Rauen et al.
Purpose: Evaluate the impact of high vs low intraoperative IOP during phacoemulsification on anterior and posterior physiology. Setting: ...
Comparisons of the clinical outcomes of Centurion® active fluidics system with a low IOP setting and gravity fluidics system with a normal IOP setting for cataract patients with low corneal endothelial cell density [0.03%]
Centurion主动灌注系统低眼压设置与重力灌注系统正常眼压设置在低角膜内皮细胞密度白内障患者中临床疗效的比较研究
Yinan Liu,Jing Hong,Xiaoyong Chen
Yinan Liu
Methods: Seventy-eight eyes of 53 patients with corneal endothelial cell density (ECD) of 500∼1500/mm2 were enrolled and randomly divided into the active fluidics system (AFS) group using an Active Sentry handpiece with 30 mmHg IOP setting (40 eyes) and the gravity fluidics system
Vitreous-lens interface changes after cataract surgery using active fluidics and active sentry with high and low infusion pressure settings [0.03%]
主动灌注和主动警戒不同灌注压力白内障手术后玻璃体-晶状体界面的变化
Hugo A Scarfone,Emilia C Rodriguez,Maira G Rufiner et al.
Hugo A Scarfone et al.
Methods: Phacoemulsification with intraocular lens implantation was performed in all patients with the Centurion Vision System equipment with active fluidics and active sentry. Patients were randomly assigned to configuration 1 or 2.
Randomized Controlled Trial
Journal of cataract and refractive surgery. 2024 Apr 1;50(4):333-338. DOI:10.1097/j.jcrs.0000000000001359 2024
Application of the Active-Fluidics System in Phacoemulsification: A Review [0.03%]
主动流体系统在超声乳化吸除术中的应用:综述
Yu Luo,Guangcan Xu,Hongyu Li et al.
Yu Luo et al.
The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is deter...
A prospective randomized clinical trial of active-fluidics versus gravity-fluidics system in phacoemulsification for age-related cataract (AGSPC) [0.03%]
主动流体学与重力流体学超声乳化吸出白内障摘除术的临床疗效观察:前瞻性随机对照试验报告
Yu Luo,Hongyu Li,Wenqian Chen et al.
Yu Luo et al.
Background: To figure out the efficacy, effects, safety and patient's subjective perceptions of phacoemulsification with the active-fluidics system (AFS). ...
Randomized Controlled Trial
Annals of medicine. 2022 Dec;54(1):1977-1987. DOI:10.1080/07853890.2022.2098375 2022
Active-fluidics versus gravity-fluidics in lens extraction: A systematic review and meta-analysis of randomized controlled trials [0.03%]
主动流体学与重力流体学在晶状体摘除中的应用:随机对照试验的系统评价和meta分析
Yu-Chen Su,Yen-Yin Lee,Yu-Chi Su
Yu-Chen Su
Objective: To investigate differences in outcomes between active-fluidics and gravity-fluidics phacoemulsification systems. Methods: We...