首页 文献索引 SCI期刊 AI助手
登录 注册
首页 正文

Journal of strength and conditioning research. 2024 Nov 1;38(11):e670-e677. doi: 10.1519/JSC.0000000000004891 Q22.52024

Validity and Reliability of the Power Slap Board as an Application to Measure Upper Body Vertical Pulling Power for Female Water Polo Players

女子水球运动员上半身垂直拉力力量测试的有效性和可靠性研究——以Power Slap板为例 翻译改进

Charmaine Lim  1, Jericho Wee  2, Melissa Lee  3, Sean Lim  4, Shina Leow  1

作者单位 +展开

作者单位

  • 1 National Youth Sports Institute, Singapore.
  • 2 Human Potential Translational Research Programme, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
  • 3 Singapore Institute of Technology, Singapore ; and.
  • 4 Ministry of Education, Singapore.
  • DOI: 10.1519/JSC.0000000000004891 PMID: 39016300

    摘要 中英对照阅读

    Lim, C, Wee, J, Lee, M, Lim, S, and Leow, S. Validity and reliability of the power slap board as an application to measure upper body vertical pulling power for female water polo players. J Strength Cond Res 38(11): e670-e677, 2024-This study examined the validity and reliability of the power slap test (PS) as an assessment for upper body pulling power to predict water polo functional performance and competitive experience of female water polo players. Seventeen female water polo players from the national and development squads were recruited. Subjects completed test-retest sessions of PS testing and 1 session of functional performance tests for the 15-m arms-only sprint (15 mAOS) and the 5-m maximum shooting velocity (5 mMSV). All PS, 15 mAOS and 5 mMSV results were compared for predictability. Power slap scores demonstrated high reliability for left PS (intraclass correlations [ICC]: 0.96, 90% confidence interval [CI]: 0.91-0.98), right PS (ICC: 0.96, 90% CI: 0.90-0.98), left and right center of mass (COM) displacement (ICC: 0.98, 90% CI: 0.96-0.99; ICC: 0.95, 90% CI: 0.88-0.98), and summed PS (ICC: 0.96, 90% CI: 0.92-0.99). All absolute PS scores and left COM displacement (COM disp L) demonstrated large correlations with the 15 mAOS times ( r = -0.542 to -0.52, r2 = 0.27-0.29, p < 0.05). No performance parameters of the PS were correlated with the 5 mMSV performance ( p > 0.05). This study validates the reliability of the PS as a dryland assessment tool for upper body pulling power. Only absolute PS scores and COM disp were validated as weak predictors of the arms-only sprint times over 15 m. Its predictive power significantly improved when considered in combination with shooting performance. All absolute and normalized kinetic and kinematic PS parameters did not predict functional performance and competitive experience.

    Keywords:power slap board; upper body vertical pulling power; female water polo players validity reliability

    Lim, C, Wee, J, Lee, M, Lim, S, and Leow, S. 干板功率拍击测试作为测量女性水球运动员上肢垂直拉力的有效性和可靠性。J Strength Cond Res 38(11): e670-e677, 2024-本研究考察了干板功率拍击测试(PS)作为评估上肢拉力的工具,以预测女性水球运动员的功能表现和竞技经验的有效性和可靠性。从国家队和发展队中招募了17名女性水球运动员。受试者完成了两次PS测试,并进行了一次功能表现测试,包括仅用臂力量完成的15米冲刺(15 mAOS)以及最大射门速度的5米测试(5 mMSV)。所有PS、15mAOS和5mMSV的结果进行了比较以评估其预测性。功率拍击得分在左侧PS(组内相关系数[ICC]:0.96,90%置信区间[CI]:0.91-0.98)、右侧PS(ICC:0.96, 90% CI: 0.90-0.98)、左和右质心位移(COM) (ICC:0.98,90% CI:0.96-0.99;ICC:0.95,90% CI:0.88-0.98)以及总PS(ICC:0.96, 90% CI: 0.92-0.99)上表现出高可靠性。所有绝对PS得分和左质心位移(COM disp L)与15 mAOS时间有较大的相关性(r = -0.542 至 -0.52,r² = 0.27-0.29, p 0.05)。本研究验证了PS作为上肢拉力干陆评估工具的可靠性。仅绝对PS得分和质心位移被确认为15米臂力量冲刺时间的弱预测因子。当将其与射门表现结合考虑时,其预测能力显著提高。所有绝对和归一化的动量和运动学PS参数无法预测功能表现和竞技经验。

    关键词:功率鞭打板; 上身垂直拉力功率; 女子水球运动员有效性可靠性

    翻译效果不满意? 用Ai改进或 寻求AI助手帮助 ,对摘要进行重点提炼
    Copyright © Journal of strength and conditioning research. 中文内容为AI机器翻译,仅供参考!

    期刊名:Journal of strength and conditioning research

    缩写:J STRENGTH COND RES

    ISSN:1064-8011

    e-ISSN:1533-4287

    IF/分区:2.5/Q2

    文章目录 更多期刊信息

    全文链接
    引文链接
    复制
    已复制!
    推荐内容
    Validity and Reliability of the Power Slap Board as an Application to Measure Upper Body Vertical Pulling Power for Female Water Polo Players