首页 文献索引 SCI期刊 AI助手
登录 注册
首页 正文

Analytical letters. 2022;55(5):796-811. doi: 10.1080/00032719.2021.1967969 Q31.62024

Development and validation of an ultraperformance liquid chromatography-tandem mass spectrometry method for quantitation of total 3,3',5-triiodo-L-thyronine and 3,3',5,5'-tetraiodo-L-thyronine in rodent serum

大鼠血清中总三碘甲状腺原氨酸和四碘甲状腺原氨酸的超高效液相色谱-串联质谱测定及验证方法 翻译改进

Suramya Waidyanatha  1, Brenda L Fletcher  2, Reshan A Fernando  2, Michelle C Cora  1, Melanie A Rehder Silinski  2

作者单位 +展开

作者单位

  • 1 Division of the National Toxicology Program, NIEHS, P.O. Box 12233, Research Triangle Park, NC 27709.
  • 2 RTI International, P.O. Box 12194, Research Triangle Park, NC 27709.
  • DOI: 10.1080/00032719.2021.1967969 PMID: 35812014

    摘要 Ai翻译

    Many environmental chemicals are known to disrupt thyroid function. Measurement of thyroid hormones in animal studies provides useful information to understand the effects of environmental chemicals on thyroid hormone metabolism. We report an efficient method, utilizing a protein precipitation followed by ultraperformance liquid chromatography-tandem mass spectrometry analysis, to quantitate total 3,3',5-triiodo-L-thyronine (triiodothyronine, T3) and total 3,3',5,5'-tetraiodo-L-thyronine (thyroxine, T4) in rodent serum. The use of synthetic serum for calibration standards eliminated the interferences from endogenous total T3 and T4 and allowed the experimental lower limits of quantitation (LOQ) to be set at the required concentration (T3, 20 ng/dL; T4, 0.5 μg/dL) to allow quantitation of endogenous concentrations. The method was linear (r>0.99; range 20.0-600 ng/dL T3, 0.500-15 μg/dL T4) with good assay recoveries (90.4-107%) for both analytes. Intra- and inter-day accuracy, estimated as percent relative error, were ≤ ±7.6% and intra- and inter-day precision, estimated as the relative standard deviation, were ≤ 5.3% for both analytes. The method may easily be adapted to a well-plate format thereby further improving the efficiency. Total T3 and T4 concentrations were stable in male and female rat and mouse serum when stored in the freezer (~ -70 °C) for up to 62 d with determined values within 92.8-111% of day 0 for both analytes. The method can be extended to quantitate total T3 and T4 concentrations in humans or other species with minimal optimization.

    Keywords: 3,3’,5-triiodo-L-thyronine; 3’,5,5’-tetraiodo-L-thyronine; rodent; serum; thyroxine; triiodothyronine; ultraperformance liquid chromatograph-tandem mass spectrometry (UPLC-MS/MS).

    Keywords:mass spectrometry method; quantitation of thyronine

    Copyright © Analytical letters. 中文内容为AI机器翻译,仅供参考!

    相关内容

    期刊名:Analytical letters

    缩写:ANAL LETT

    ISSN:0003-2719

    e-ISSN:1532-236X

    IF/分区:1.6/Q3

    文章目录 更多期刊信息

    全文链接
    引文链接
    复制
    已复制!
    推荐内容
    Development and validation of an ultraperformance liquid chromatography-tandem mass spectrometry method for quantitation of total 3,3',5-triiodo-L-thyronine and 3,3',5,5'-tetraiodo-L-thyronine in rodent serum