Physical review. C. 2017 Jul;96(1):014613. doi: 10.1103/physrevc.96.014613 Q23.22024

Half-life of 51Mn

mn-51的半衰期 翻译改进

Stephen A Graves  1, Paul A Ellison  1, Hector F Valdovinos  1, Todd E Barnhart  1, Robert J Nickles  1, Jonathan W Engle  1

作者单位 +展开

作者单位

  • 1 Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA.
  • DOI: 10.1103/physrevc.96.014613 PMID: 34327291

    摘要 Ai翻译

    The half-life of 51Mn was measured by serial gamma spectrometry of the 511-keV annihilation photon following decay by β + emission. Data were collected every 100 seconds for 100,000-230,000 seconds within each measurement (n = 4). The 511-keV incidence rate was calculated from the 511-keV spectral peak area and count duration, corrected for detector dead time and radioactive decay. Least-squares regression analysis was used to determine the half-life of 51Mn while accounting for the presence of background contaminants, notably 55Co. The result was 45.59 ± 0.07 min, which is the highest precision measurement to date and disagrees with the current Nuclear Data Sheets value by over 6σ.

    Keywords:half-life; manganese-51

    关键词:半衰期; 锰51

    Copyright © Physical review. C. 中文内容为AI机器翻译,仅供参考!