首页 正文

Journal of clinical orthopaedics and trauma. 2021 May 15:18:216-223. doi: 10.1016/j.jcot.2021.04.030 0.02024

Does the use of intraoperative CT scan improve outcomes in Orthopaedic surgery? A systematic review and meta-analysis of 871 cases

术中使用CT扫描是否能改善骨科手术的预后?871例系统评价和荟萃分析 翻译改进

Vishal Kumar  1, Vishnu Baburaj  1, Sandeep Patel  1, Siddhartha Sharma  1, Raju Vaishya  2

作者单位 +展开

作者单位

  • 1 Department of Orthopaedics, Postgraduate Institute of Medial Education and Research, Chandigarh, India.
  • 2 Department of Orthopaedics, Indraprastha Apollo Hospitals, New Delhi, India.
  • DOI: 10.1016/j.jcot.2021.04.030 PMID: 34040978

    摘要 Ai翻译

    Background: Intraoperative imaging is frequently made use of in Orthopaedic surgery. Historically, conventional 2-dimensional fluoroscopy has been extensively used for this purpose. However, 2D imaging falls short when it is required to visualise complex anatomical regions such as pelvis, spine, foot and ankle etc. Intraoperative 3D imaging was introduced to counter these limitations, and is increasingly being employed in various sub-specialities of Orthopaedic Surgery.

    Objectives: This review aims to outline the clinical and radiological outcomes of surgeries done under the guidance of intraoperative 3D imaging and compare them to those done under conventional 2D fluoroscopy.

    Methods: Three electronic databases (PubMed, Embase and Scopus) were searched for relevant studies that directly compared intraoperative 3D imaging with conventional fluoroscopy. Case series on intraoperative 3D imaging were also included for qualitative synthesis. The outcomes evaluated included accuracy of implant placement, mean surgical duration and rate of revision surgery due to faulty implants.

    Results: A total of 31 studies from sub-specialities of spine surgery, pelvi-acetabular surgery, foot and ankle surgery and trauma surgery, having data on a total of 658 patients were analysed. The study groups which had access to intraoperative 3D imaging was found to have significantly increased accuracy of implant positioning (Odds Ratio 0.35 [0.20, 0.62], p = 0.0002) without statistically significant difference in mean surgical time (p = 0.57). Analysis of the studies that included clinical follow up showed that the use of intraoperative 3D imaging led to a significant decrease in the need for revision surgeries due to faulty implant placement.

    Conclusion: There is sufficient evidence that the application of intraoperative 3D imaging leads to precise implant positioning and improves the radiological outcome. Further research in the form of prospective studies with long term follow up is required to determine whether this superior radiological outcome translates to better clinical results in the long run.

    Keywords: 3D C-Arm; 3D fluoroscopy; Intraoperative 3D imaging; Intraoperative CT; Intraoperative computed tomography; Orthopaedics; Spine surgery; iCT.

    Keywords:intraoperative ct scan; orthopedic surgery; systematic review; meta-analysis

    Copyright © Journal of clinical orthopaedics and trauma. 中文内容为AI机器翻译,仅供参考!