The heart rate (HR) measurements based on the camera (visible light) can be used to detect HR in non-contact mode, which has great application prospects both in the clinical application and home health care. However, CMOS sensors equipped with “rolling shutters”, which distinguishes different lines per frame to become light sensitive at different moments in time, and stylized dithering of image acquisition (IMAQ) time caused by different computer programs running in the background will greatly influence the accuracy of the measured HR. In this paper, we analyze the phase error caused by CMOS sensor and the system error introduced by system sampling clock jitters. According to derivation, we propose two methods, amplitude-frequency superposition and a cubic spline interpolation reconstruction method based on actual schedules, that can be widely utilized in computer vision to overcome the camera phase error and sampling time fluctuation error. Amplitude of signal is analyzed and processed in amplitude-frequency domain in the method of amplitude-frequency superposition, which ignores the signal phase. Thus it can eliminate the phase error effectively. The cubic spline interpolation reconstruction method based on actual schedules can reconstructed the non-uniform sampling of images as uniform ones, so it can eliminate the system error involved by the system clock jitters. What’s more, the properties of the methods are tested by applying them to both simulation experiments and real HR measurements. In the simulation, amplitude of measured signal is improved 4.58% relative to the amplitude measured without the method of amplitude-frequency superposition; root mean square error of signal’s frequency, detected by the cubic spline interpolation reconstruction method based on actual schedules, is reduced more than 30%. In the real HR measurements, the amplitude of HR is raised to 33.5% relatively based on amplitude-frequency superposition. And the accuracy of HR is raised to approximately 40% by the method of cubic spline interpolation reconstruction method based on actual schedules. Therefore, the simulation experiments and real HR measurement proof that we can effectively eliminate the camera phase error based on the amplitude-frequency superposition extraction method, and the cubic spline interpolation based on the timetable method can effectively reduce the random error in IMAQ due to system clock jitters. These methods can both be widely used in dynamic signal detection based on machine vision.
Guang pu xue yu guang pu fen xi = Guang pu. 2017 Feb;37(2):651-8. Q40.72024
Improving the Accuracy of Camera-Based Heart Rate Measurement
基于摄像头的心率测量精度改进方法 翻译改进
作者单位 +展开
作者单位
PMID: 30292188
摘要 Ai翻译
Keywords:accuracy improvement
关键词:基于摄像头的心率测量; 准确性改进
相关内容
-
Improving accuracy of breast cancer biomarker testing in India
提高印度乳腺癌生物标志物检测的准确性
The Indian journal of medical research. 2017 Oct;146(4):449-458.
-
The Rapid Coronavirus Antibody Test: Can We Improve Accuracy?
快速冠状病毒抗体检测:我们能否提高准确性?
Frontiers in medicine. 2020 Sep 2:7:569.
-
Improving the accuracy of suicide attempter classification
提高自杀未遂分类的准确性
Artificial intelligence in medicine. 2011 Jul;52(3):165-8.
-
Research on improving the accuracy of laser-induced breakdown spectroscopy analysis by considering plasma attenuation rate characteristics
通过考虑等离子体衰减率特性提高激光诱导击穿光谱分析精度的研究
Analytica chimica acta. 2024 Jan 25:1287:342065.
-
Method for improving accuracy in full evaporation headspace analysis
全挥发顶空分析法准确度提升方法研究
Journal of separation science. 2017 May;40(9):1974-1978.
-
A method improving the accuracy of fluorescence recovery after photobleaching analysis
一种提高光漂白后荧光恢复分析准确性的方法
Biophysical journal. 2008 Dec;95(11):5334-48.
-
Improved accuracy in time-resolved diffuse reflectance spectroscopy
改进的时间分辨漫反射光谱的精度
Optics express. 2008 Jul 7;16(14):10440-54.
-
Improving accuracy in a computerized immunization registry
提高计算机化免疫登记的准确性
Ambulatory pediatrics : the official journal of the Ambulatory Pediatric Association. 2002 May-Jun;2(3):187-92.