首页 正文

Journal of biotechnology. 2008 Feb 29;133(4):490-6. doi: 10.1016/j.jbiotec.2007.11.010 Q23.92025

Design and validation of a dynamic flow perfusion bioreactor for use with compliant tissue engineering scaffolds

一种用于顺应性组织工程支架的动态流体灌注生物反应器的设计与验证 翻译改进

Michael J Jaasma  1, Niamh A Plunkett, Fergal J O'Brien

作者单位 +展开

作者单位

  • 1 Department of Anatomy, Royal College of Surgeons in Ireland, 123 St. Stephen's Green, Dublin 2, Ireland.
  • DOI: 10.1016/j.jbiotec.2007.11.010 PMID: 18221813

    摘要 Ai翻译

    In tissue engineering, flow perfusion bioreactors can be used to enhance nutrient diffusion while mechanically stimulating cells to increase matrix production. The goal of this study was to design and validate a dynamic flow perfusion bioreactor for use with compliant scaffolds. Using a non-permanent staining technique, scaffold perfusion was verified for flow rates of 0.1-2.0 mL/min. Flow analysis revealed that steady, pulsatile and oscillatory flow profiles were effectively transferred from the pump to the scaffold. Compared to static culture, bioreactor culture of osteoblast-seeded collagen-GAG scaffolds led to a 27-34% decrease in cell number but stimulated an 800-1200% increase in the production of prostaglandin E(2), an early-stage bone formation marker. This validated flow perfusion bioreactor provides the basis for optimisation of bioreactor culture in tissue engineering applications.

    Keywords:tissue engineering scaffolds

    关键词:组织工程支架

    Copyright © Journal of biotechnology. 中文内容为AI机器翻译,仅供参考!

    相关内容

    期刊名:Journal of biotechnology

    缩写:J BIOTECHNOL

    ISSN:0168-1656

    e-ISSN:1873-4863

    IF/分区:3.9/Q2

    文章目录 更多期刊信息

    全文链接
    引文链接
    复制
    已复制!
    推荐内容
    Design and validation of a dynamic flow perfusion bioreactor for use with compliant tissue engineering scaffolds